Time:

Nov 14,2023

Source:

Author:

Reason:The scanner, reflector and transcription component are problematic; the protection cover is unopened, the conductive steel sheet of the magnetic roller and the conductive metal wire of the machine do not contact each other;The OPC drum gear is loose.

Solution:Check the scanner, reflector and transcription component; take out the toner bin and reinstall it, make sure the protection cover is totally open, and the contact between the conductive steel sheet of the magnetic roller and the conductive metal wire of the machine is good; replace the OPC drum.